Project:
Date: 2026-03-07
Prepared By: AI Pump Selection Assistant
Prepared For:
Application: Water Supply
Report ID: APE-20260307-56MEDIVANE2P
| Parameter | Value |
|---|---|
| Manufacturer | APE PUMPS |
| Pump Model | 5/6 MEDIVANE 2P |
| Pump Type | HSC |
| Pump Range | Industrial |
| Parameter | Value |
|---|---|
| Pump Speed | 2900 RPM |
| Impeller Diameter | 360.0mm |
| Application | Water Supply |
| No of Stages | 1 |
The APE PUMPS Model 5/6 MEDIVANE 2P, configured with a 360.0mm impeller for the duty of 633.2 m³/hr at 162.7m head represents an optimal choice from an energy efficiency perspective.
At a flow rate of 633.2 m³/hr, this pump configuration will deliver a head of approximately 162.7 m. This directly meets the specified head and flow requirements.
The pump will operate at an efficiency of approximately 67.0% at this duty point.
Reasoning & Insight: This operating point provides acceptable efficiency for this application. This efficiency level:
The anticipated absorbed power at the duty point is approximately 419.0 kW.
The NPSHr for the pump at 633.2 m³/hr is approximately 12.2 meters.
The HSC design is well-suited for "Water Supply" applications, particularly for installations requiring reliable and efficient fluid transfer.