Pump Selection Report

Project:

Date: 2026-03-07

Prepared By: AI Pump Selection Assistant

Prepared For:

Application: Water Supply

Report ID: APE-20260307-24WLN46A

assignment System Requirements
Flow Rate
8088.0 m³/hr
Total Head
179.0 m

1. Selected Pump Summary Good

Overall Suitability Score
96%
Parameter Value
Manufacturer APE PUMPS
Pump Model 24 WLN 46A
Pump Type HSC
Pump Range Industrial
Parameter Value
Pump Speed 995 RPM
Impeller Diameter 1085.0mm
Application Water Supply
No of Stages 1

2. Duty Point Requirements

8088.0 m³/hr
Required Flow Rate
179.0 m
Total Head
Water Type
Fluid
Performance Achievement
8088.0
Achieved Flow (m³/hr)
179.0
Achieved Head (m)
75.0%
Efficiency
5260.2
Power (kW)

Interactive Performance Analysis

Click and drag to zoom • Double-click to reset • Hover for detailed values

Operating Point Analysis: The selected pump operates at 8088.0 m³/hr and 179.0 m head with 75.0% efficiency. Within Curve
Head vs Flow Rate with BEP Operating Range
179.0 m BEP Zone
Efficiency vs Flow Rate with BEP Analysis
75.0% BEP: 75.0%
Power Consumption vs Flow Rate with System Analysis
5260.2 kW System Load
NPSH Required vs Flow Rate with Cavitation Analysis
7.1 m Cavitation Zone
Best Efficiency Point (BEP) Analysis
BEP Operating Range:
6470.0 - 8897.0 m³/hr
80% - 110% of duty point
Operating Position:
Within BEP Range
Optimal efficiency zone
System Curve Match:
Good Match
Static: 53.7m, Dynamic: 125.3m
Efficiency Rating:
Good (75.0%)
Operational efficiency

4. Performance Analysis & Alignment with Requirements

The APE PUMPS Model 24 WLN 46A, configured with a 1085.0mm impeller for the duty of 8088.0 m³/hr at 179.0m head represents an optimal choice from an energy efficiency perspective.

Meeting the Duty Point:

At a flow rate of 8088.0 m³/hr, this pump configuration will deliver a head of approximately 179.0 m. This directly meets the specified head and flow requirements.

Reasoning: The operating point (8088.0 m³/hr, 179.0 m) falls within the performance curve for the 1085.0mm impeller.
Operational Efficiency:

The pump will operate at an efficiency of approximately 75.0% at this duty point.

Reasoning & Insight: This operating point provides good efficiency performance. Operating at this efficiency level:

  • Maximizes energy efficiency, leading to lower operational costs over the pump's lifespan
  • Minimizes stress on pump components (bearings, seals), contributing to longer service life and reduced maintenance requirements
  • Ensures smooth and stable hydraulic operation
Power Consumption:

The anticipated absorbed power at the duty point is approximately 5260.2 kW.

Reasoning & Insight: This is derived from the power curve for the 1085.0mm impeller at a flow of 8088.0 m³/hr. Selecting a motor with an appropriate service factor above this value is recommended. The high operational efficiency contributes to a relatively optimized power draw for the work being done.
Net Positive Suction Head Required (NPSHr):

The NPSHr for the pump at 8088.0 m³/hr is approximately 7.1 meters.

Reasoning & Insight: This value is taken from the NPSH curve. It is crucial that the Net Positive Suction Head Available (NPSHa) in the system significantly exceeds this NPSHr value to prevent cavitation. Cavitation can lead to noise, vibration, damage to the impeller, and a reduction in pump performance. Ensuring adequate NPSHa is a critical system design consideration for optimal pump operation.
Pump Type Alignment:

The HSC design is well-suited for "Water Supply" applications, particularly for installations requiring reliable and efficient fluid transfer.

Reasoning & Insight: This pump type provides a good balance between flow rate and head generation, making it suitable for the specified application requirements. The selected impeller configuration ensures optimal performance characteristics for the given duty point.

5. AI-Powered Technical Reasoning

This pump selection provides optimal performance characteristics for the specified duty point, ensuring reliable operation within the design parameters.

The selected impeller size and operating conditions balance efficiency, power consumption, and hydraulic performance for this application.

Performance curves indicate stable operation across the expected flow range with appropriate NPSH margins for typical installations.

5. Key Insights & Recommendations

Optimal Selection for Efficiency:

The selection of the 24 WLN 46A with a 1085.0mm impeller for the duty of 8088.0 m³/hr at 179.0m head represents an optimal choice from an energy efficiency perspective.

System NPSH Verification:

Critical attention must be paid to the system's NPSHa to ensure it is greater than the pump's 7.1m NPSHr to guarantee cavitation-free operation.

Motor Sizing:

A motor should be selected based on the 5260.2 kW power consumption, incorporating an appropriate service factor as per standard engineering practice.

Robust Design for Application:

The pump's specifications align well with standard requirements for robust Water Supply applications.

Operating Results Summary

Parameter Operating Point Units Status
Pump Model 24 WLN 46A - Selected
Pump Type Vertical Turbine Pump (VTP) - Industrial
Speed 995 rpm Standard
Impeller Diameter 1085.0 mm Optimal
Flow Rate 8088.0 m³/hr Target
Head 179.0 m Achieved
Efficiency 75.0 % Excellent
Power 5260.2 kW Calculated
NPSHr 7.1 m Available
Operating results based on authentic APE pump performance data at duty point: 8088 m³/hr @ 179.0m head
Disclaimer

This report is based on the performance data presented in the APE Pumps characteristic curve sheet for the 24 WLN 46A model. Actual performance may vary based on site conditions, fluid properties, and installation specifics.

AI Technical Expert Analysis