Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
6131.0 m³/hr Required
65.5 m Head Required
Application Requirements
Flow Rate: 6131.0 m³/hr
Head: 65.5 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
700-600-710 6P
20 WLN 28C
24 WLN 42A
20 WLN 26B
24 WLN 46A
20 WLN 28B 6P
30 WLN 41C
20/24 DV MEDI
20/24 CME
16 WLN 35 C
Add to Shortlist
Overall Score 72.9/100 59.6/100 59.5/100 59.4/100 59.1/100 51.3/100 47.7/100 43.4/100 26.6/100 24.2/100
Pump Type
Efficiency (%) 85.0% 86.5% 82.6% 55.0% 89.7% 87.9% 80.0% 92.2% 84.1% 80.5%
Power Consumption (kW) 1287.4 1265.1 1703.8 1989.6 2766.6 1244.9 1367.9 1187.5 1301.8 1359.4
Head Accuracy 65.5m 65.5m 84.2m 65.5m 148.5m 65.5m 65.5m 65.5m 65.5m 65.5m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 85.0%, Head error: 0.0% Efficiency: 86.5%, Head error: 0.0% Efficiency: 82.6%, Head error: 0.0% Efficiency: 55.0%, Head error: 0.0% Efficiency: 89.7%, Head error: 0.0% Efficiency: 87.9%, Head error: 0.0% Efficiency: 80.0%, Head error: 0.0% Efficiency: 92.2%, Head error: 0.0% Efficiency: 84.1%, Head error: 0.0% Efficiency: 80.5%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
700-600-710 6P
R28,194,498/year
1287.4 kW × 8760h × R2.49/kWh
20 WLN 28C
R27,705,581/year
1265.1 kW × 8760h × R2.49/kWh
24 WLN 42A
R37,313,746/year
1703.8 kW × 8760h × R2.49/kWh
20 WLN 26B
R43,573,313/year
1989.6 kW × 8760h × R2.49/kWh
24 WLN 46A
R60,588,343/year
2766.6 kW × 8760h × R2.49/kWh
20 WLN 28B 6P
R27,264,296/year
1244.9 kW × 8760h × R2.49/kWh
30 WLN 41C
R29,956,660/year
1367.9 kW × 8760h × R2.49/kWh
20/24 DV MEDI
R26,006,863/year
1187.5 kW × 8760h × R2.49/kWh
20/24 CME
R28,509,770/year
1301.8 kW × 8760h × R2.49/kWh
16 WLN 35 C
R29,770,575/year
1359.4 kW × 8760h × R2.49/kWh
10-Year Total Cost
700-600-710 6P
R331,945
Initial + 10-year energy cost
20 WLN 28C
R327,056
Initial + 10-year energy cost
24 WLN 42A
R423,137
Initial + 10-year energy cost
20 WLN 26B
R485,733
Initial + 10-year energy cost
24 WLN 46A
R655,883
Initial + 10-year energy cost
20 WLN 28B 6P
R322,643
Initial + 10-year energy cost
30 WLN 41C
R349,567
Initial + 10-year energy cost
20/24 DV MEDI
R310,069
Initial + 10-year energy cost
20/24 CME
R335,098
Initial + 10-year energy cost
16 WLN 35 C
R347,706
Initial + 10-year energy cost
Annual Cost Comparison
700-600-710 6P
Baseline
Reference point
20 WLN 28C
+R488,918/year
Cost savings vs baseline
24 WLN 42A
-R9,119,248/year
Additional cost vs baseline
20 WLN 26B
-R15,378,815/year
Additional cost vs baseline
24 WLN 46A
-R32,393,845/year
Additional cost vs baseline
20 WLN 28B 6P
+R930,203/year
Cost savings vs baseline
30 WLN 41C
-R1,762,162/year
Additional cost vs baseline
20/24 DV MEDI
+R2,187,635/year
Cost savings vs baseline
20/24 CME
-R315,272/year
Additional cost vs baseline
16 WLN 35 C
-R1,576,077/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 20/24 DV MEDI (92.2% efficiency)
Lowest Operating Cost: 20/24 DV MEDI (R26,006,863/year)
Annual Cost Range: R34,581,480 difference between highest and lowest
10-Year Impact: R345,814,797 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

700-600-710 6P

72.9
Overall Score
Efficiency 85.0%
Power 1287.4 kW
Head 65.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

20 WLN 28C

59.6
Overall Score
Efficiency 86.5%
Power 1265.1 kW
Head 65.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

24 WLN 42A

59.5
Overall Score
Efficiency 82.6%
Power 1703.8 kW
Head 84.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

20 WLN 26B

59.4
Overall Score
Efficiency 55.0%
Power 1989.6 kW
Head 65.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

24 WLN 46A

59.1
Overall Score
Efficiency 89.7%
Power 2766.6 kW
Head 148.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20 WLN 28B 6P

51.3
Overall Score
Efficiency 87.9%
Power 1244.9 kW
Head 65.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

30 WLN 41C

47.7
Overall Score
Efficiency 80.0%
Power 1367.9 kW
Head 65.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

20/24 DV MEDI

43.4
Overall Score
Efficiency 92.2%
Power 1187.5 kW
Head 65.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

20/24 CME

26.6
Overall Score
Efficiency 84.1%
Power 1301.8 kW
Head 65.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

16 WLN 35 C

24.2
Overall Score
Efficiency 80.5%
Power 1359.4 kW
Head 65.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection