Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
4980.0 m³/hr Required
56.0 m Head Required
Application Requirements
Flow Rate: 4980.0 m³/hr
Head: 56.0 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
20 WLN 26B
20 WLN 28B 6P
700-600-710 6P
20 WLN 28C
20/24 CME
20/24 DV MEDI
20 D.S
20 WLN 26A
24 WLN 46A
30 WLN 41C
Add to Shortlist
Overall Score 81.4/100 79.9/100 78.8/100 71.7/100 69.3/100 67.8/100 57.8/100 52.5/100 52.2/100 45.2/100
Pump Type
Efficiency (%) 80.0% 89.7% 85.0% 87.8% 84.1% 92.3% 77.7% 83.0% 88.0% 73.0%
Power Consumption (kW) 949.9 913.4 894.1 1108.0 904.1 973.2 978.6 915.6 1920.4 1188.7
Head Accuracy 56.0m 60.4m 56.0m 71.7m 56.0m 66.2m 56.0m 56.0m 124.5m 63.9m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 80.0%, Head error: 0.0% Efficiency: 89.7%, Head error: 0.0% Efficiency: 85.0%, Head error: 0.0% Efficiency: 87.8%, Head error: 0.0% Efficiency: 84.1%, Head error: 0.0% Efficiency: 92.3%, Head error: 0.0% Efficiency: 77.7%, Head error: 0.0% Efficiency: 83.0%, Head error: 0.0% Efficiency: 88.0%, Head error: 0.0% Efficiency: 73.0%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
20 WLN 26B
R20,803,576/year
949.9 kW × 8760h × R2.49/kWh
20 WLN 28B 6P
R20,003,701/year
913.4 kW × 8760h × R2.49/kWh
700-600-710 6P
R19,579,826/year
894.1 kW × 8760h × R2.49/kWh
20 WLN 28C
R24,266,207/year
1108.0 kW × 8760h × R2.49/kWh
20/24 CME
R19,798,783/year
904.1 kW × 8760h × R2.49/kWh
20/24 DV MEDI
R21,312,532/year
973.2 kW × 8760h × R2.49/kWh
20 D.S
R21,430,420/year
978.6 kW × 8760h × R2.49/kWh
20 WLN 26A
R20,051,640/year
915.6 kW × 8760h × R2.49/kWh
24 WLN 46A
R42,057,702/year
1920.4 kW × 8760h × R2.49/kWh
30 WLN 41C
R26,032,880/year
1188.7 kW × 8760h × R2.49/kWh
10-Year Total Cost
20 WLN 26B
R258,036
Initial + 10-year energy cost
20 WLN 28B 6P
R250,037
Initial + 10-year energy cost
700-600-710 6P
R245,798
Initial + 10-year energy cost
20 WLN 28C
R292,662
Initial + 10-year energy cost
20/24 CME
R247,988
Initial + 10-year energy cost
20/24 DV MEDI
R263,125
Initial + 10-year energy cost
20 D.S
R264,304
Initial + 10-year energy cost
20 WLN 26A
R250,516
Initial + 10-year energy cost
24 WLN 46A
R470,577
Initial + 10-year energy cost
30 WLN 41C
R310,329
Initial + 10-year energy cost
Annual Cost Comparison
20 WLN 26B
Baseline
Reference point
20 WLN 28B 6P
+R799,876/year
Cost savings vs baseline
700-600-710 6P
+R1,223,750/year
Cost savings vs baseline
20 WLN 28C
-R3,462,631/year
Additional cost vs baseline
20/24 CME
+R1,004,794/year
Cost savings vs baseline
20/24 DV MEDI
-R508,956/year
Additional cost vs baseline
20 D.S
-R626,844/year
Additional cost vs baseline
20 WLN 26A
+R751,936/year
Cost savings vs baseline
24 WLN 46A
-R21,254,125/year
Additional cost vs baseline
30 WLN 41C
-R5,229,304/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 20/24 DV MEDI (92.3% efficiency)
Lowest Operating Cost: 700-600-710 6P (R19,579,826/year)
Annual Cost Range: R22,477,875 difference between highest and lowest
10-Year Impact: R224,778,753 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

20 WLN 26B

81.4
Overall Score
Efficiency 80.0%
Power 949.9 kW
Head 56.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

20 WLN 28B 6P

79.9
Overall Score
Efficiency 89.7%
Power 913.4 kW
Head 60.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

700-600-710 6P

78.8
Overall Score
Efficiency 85.0%
Power 894.1 kW
Head 56.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

20 WLN 28C

71.7
Overall Score
Efficiency 87.8%
Power 1108.0 kW
Head 71.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

20/24 CME

69.3
Overall Score
Efficiency 84.1%
Power 904.1 kW
Head 56.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20/24 DV MEDI

67.8
Overall Score
Efficiency 92.3%
Power 973.2 kW
Head 66.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

20 D.S

57.8
Overall Score
Efficiency 77.7%
Power 978.6 kW
Head 56.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

20 WLN 26A

52.5
Overall Score
Efficiency 83.0%
Power 915.6 kW
Head 56.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

24 WLN 46A

52.2
Overall Score
Efficiency 88.0%
Power 1920.4 kW
Head 124.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

30 WLN 41C

45.2
Overall Score
Efficiency 73.0%
Power 1188.7 kW
Head 63.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection