Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
4878.0 m³/hr Required
57.4 m Head Required
Application Requirements
Flow Rate: 4878.0 m³/hr
Head: 57.4 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
20 WLN 26B
20 WLN 28B 6P
700-600-710 6P
20 WLN 28C
20/24 DV MEDI
20/24 CME
20 WLN 26A
20 D.S
24 WLN 46A
30 WLN 41C
Add to Shortlist
Overall Score 83.8/100 81.0/100 77.1/100 71.9/100 70.9/100 69.2/100 68.8/100 62.3/100 51.4/100 44.5/100
Pump Type
Efficiency (%) 80.0% 90.0% 81.0% 87.6% 93.1% 84.1% 88.5% 77.7% 87.8% 72.0%
Power Consumption (kW) 953.7 903.0 942.0 1097.8 959.3 907.7 862.1 982.5 1903.5 1182.5
Head Accuracy 57.4m 61.1m 57.4m 72.4m 67.2m 57.4m 57.4m 57.4m 125.7m 64.1m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 80.0%, Head error: 0.0% Efficiency: 90.0%, Head error: 0.0% Efficiency: 81.0%, Head error: 0.0% Efficiency: 87.6%, Head error: 0.0% Efficiency: 93.1%, Head error: 0.0% Efficiency: 84.1%, Head error: 0.0% Efficiency: 88.5%, Head error: 0.0% Efficiency: 77.7%, Head error: 0.0% Efficiency: 87.8%, Head error: 0.0% Efficiency: 72.0%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
20 WLN 26B
R20,886,906/year
953.7 kW × 8760h × R2.49/kWh
20 WLN 28B 6P
R19,775,043/year
903.0 kW × 8760h × R2.49/kWh
700-600-710 6P
R20,629,055/year
942.0 kW × 8760h × R2.49/kWh
20 WLN 28C
R24,041,513/year
1097.8 kW × 8760h × R2.49/kWh
20/24 DV MEDI
R21,008,473/year
959.3 kW × 8760h × R2.49/kWh
20/24 CME
R19,878,104/year
907.7 kW × 8760h × R2.49/kWh
20 WLN 26A
R18,880,822/year
862.1 kW × 8760h × R2.49/kWh
20 D.S
R21,516,268/year
982.5 kW × 8760h × R2.49/kWh
24 WLN 46A
R41,687,723/year
1903.5 kW × 8760h × R2.49/kWh
30 WLN 41C
R25,897,473/year
1182.5 kW × 8760h × R2.49/kWh
10-Year Total Cost
20 WLN 26B
R258,869
Initial + 10-year energy cost
20 WLN 28B 6P
R247,750
Initial + 10-year energy cost
700-600-710 6P
R256,291
Initial + 10-year energy cost
20 WLN 28C
R290,415
Initial + 10-year energy cost
20/24 DV MEDI
R260,085
Initial + 10-year energy cost
20/24 CME
R248,781
Initial + 10-year energy cost
20 WLN 26A
R238,808
Initial + 10-year energy cost
20 D.S
R265,163
Initial + 10-year energy cost
24 WLN 46A
R466,877
Initial + 10-year energy cost
30 WLN 41C
R308,975
Initial + 10-year energy cost
Annual Cost Comparison
20 WLN 26B
Baseline
Reference point
20 WLN 28B 6P
+R1,111,863/year
Cost savings vs baseline
700-600-710 6P
+R257,851/year
Cost savings vs baseline
20 WLN 28C
-R3,154,607/year
Additional cost vs baseline
20/24 DV MEDI
-R121,567/year
Additional cost vs baseline
20/24 CME
+R1,008,802/year
Cost savings vs baseline
20 WLN 26A
+R2,006,084/year
Cost savings vs baseline
20 D.S
-R629,362/year
Additional cost vs baseline
24 WLN 46A
-R20,800,817/year
Additional cost vs baseline
30 WLN 41C
-R5,010,567/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 20/24 DV MEDI (93.1% efficiency)
Lowest Operating Cost: 20 WLN 26A (R18,880,822/year)
Annual Cost Range: R22,806,901 difference between highest and lowest
10-Year Impact: R228,069,009 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

20 WLN 26B

83.8
Overall Score
Efficiency 80.0%
Power 953.7 kW
Head 57.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

20 WLN 28B 6P

81.0
Overall Score
Efficiency 90.0%
Power 903.0 kW
Head 61.1 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

700-600-710 6P

77.1
Overall Score
Efficiency 81.0%
Power 942.0 kW
Head 57.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

20 WLN 28C

71.9
Overall Score
Efficiency 87.6%
Power 1097.8 kW
Head 72.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

20/24 DV MEDI

70.9
Overall Score
Efficiency 93.1%
Power 959.3 kW
Head 67.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20/24 CME

69.2
Overall Score
Efficiency 84.1%
Power 907.7 kW
Head 57.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

20 WLN 26A

68.8
Overall Score
Efficiency 88.5%
Power 862.1 kW
Head 57.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

20 D.S

62.3
Overall Score
Efficiency 77.7%
Power 982.5 kW
Head 57.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

24 WLN 46A

51.4
Overall Score
Efficiency 87.8%
Power 1903.5 kW
Head 125.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

30 WLN 41C

44.5
Overall Score
Efficiency 72.0%
Power 1182.5 kW
Head 64.1 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection