Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
4752.0 m³/hr Required
42.0 m Head Required
Application Requirements
Flow Rate: 4752.0 m³/hr
Head: 42.0 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
20 WLN 26B
32 XHC 6P
20/24 DV CME
700-600-710 6P
20 WLN 28C
20 WLN 28B 6P
20 WLN 28B 8P
20/24 CME
20/24 CME2
20/24 DV MEDI
Add to Shortlist
Overall Score 80.4/100 79.7/100 74.2/100 71.6/100 69.7/100 67.6/100 65.6/100 64.0/100 64.0/100 63.4/100
Pump Type
Efficiency (%) 87.3% 85.0% 90.5% 88.8% 87.5% 90.3% 87.0% 84.2% 84.2% 94.2%
Power Consumption (kW) 628.8 639.8 601.0 839.7 826.6 889.5 625.1 854.4 854.4 941.6
Head Accuracy 42.4m 42.0m 42.0m 57.6m 55.9m 62.0m 42.0m 55.5m 55.5m 68.5m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 87.3%, Head error: 0.0% Efficiency: 85.0%, Head error: 0.0% Efficiency: 90.5%, Head error: 0.0% Efficiency: 88.8%, Head error: 0.0% Efficiency: 87.5%, Head error: 0.0% Efficiency: 90.3%, Head error: 0.0% Efficiency: 87.0%, Head error: 0.0% Efficiency: 84.2%, Head error: 0.0% Efficiency: 84.2%, Head error: 0.0% Efficiency: 94.2%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
20 WLN 26B
R13,771,421/year
628.8 kW × 8760h × R2.49/kWh
32 XHC 6P
R14,012,562/year
639.8 kW × 8760h × R2.49/kWh
20/24 DV CME
R13,160,958/year
601.0 kW × 8760h × R2.49/kWh
700-600-710 6P
R18,389,540/year
839.7 kW × 8760h × R2.49/kWh
20 WLN 28C
R18,102,277/year
826.6 kW × 8760h × R2.49/kWh
20 WLN 28B 6P
R19,480,619/year
889.5 kW × 8760h × R2.49/kWh
20 WLN 28B 8P
R13,690,435/year
625.1 kW × 8760h × R2.49/kWh
20/24 CME
R18,710,572/year
854.4 kW × 8760h × R2.49/kWh
20/24 CME2
R18,710,572/year
854.4 kW × 8760h × R2.49/kWh
20/24 DV MEDI
R20,622,091/year
941.6 kW × 8760h × R2.49/kWh
10-Year Total Cost
20 WLN 26B
R187,714
Initial + 10-year energy cost
32 XHC 6P
R190,126
Initial + 10-year energy cost
20/24 DV CME
R181,610
Initial + 10-year energy cost
700-600-710 6P
R233,895
Initial + 10-year energy cost
20 WLN 28C
R231,023
Initial + 10-year energy cost
20 WLN 28B 6P
R244,806
Initial + 10-year energy cost
20 WLN 28B 8P
R186,904
Initial + 10-year energy cost
20/24 CME
R237,106
Initial + 10-year energy cost
20/24 CME2
R237,106
Initial + 10-year energy cost
20/24 DV MEDI
R256,221
Initial + 10-year energy cost
Annual Cost Comparison
20 WLN 26B
Baseline
Reference point
32 XHC 6P
-R241,141/year
Additional cost vs baseline
20/24 DV CME
+R610,462/year
Cost savings vs baseline
700-600-710 6P
-R4,618,119/year
Additional cost vs baseline
20 WLN 28C
-R4,330,856/year
Additional cost vs baseline
20 WLN 28B 6P
-R5,709,199/year
Additional cost vs baseline
20 WLN 28B 8P
+R80,986/year
Cost savings vs baseline
20/24 CME
-R4,939,151/year
Additional cost vs baseline
20/24 CME2
-R4,939,151/year
Additional cost vs baseline
20/24 DV MEDI
-R6,850,670/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 20/24 DV MEDI (94.2% efficiency)
Lowest Operating Cost: 20/24 DV CME (R13,160,958/year)
Annual Cost Range: R7,461,133 difference between highest and lowest
10-Year Impact: R74,611,329 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

20 WLN 26B

80.4
Overall Score
Efficiency 87.3%
Power 628.8 kW
Head 42.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

32 XHC 6P

79.7
Overall Score
Efficiency 85.0%
Power 639.8 kW
Head 42.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

20/24 DV CME

74.2
Overall Score
Efficiency 90.5%
Power 601.0 kW
Head 42.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

700-600-710 6P

71.6
Overall Score
Efficiency 88.8%
Power 839.7 kW
Head 57.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

20 WLN 28C

69.7
Overall Score
Efficiency 87.5%
Power 826.6 kW
Head 55.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20 WLN 28B 6P

67.6
Overall Score
Efficiency 90.3%
Power 889.5 kW
Head 62.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

20 WLN 28B 8P

65.6
Overall Score
Efficiency 87.0%
Power 625.1 kW
Head 42.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

20/24 CME

64.0
Overall Score
Efficiency 84.2%
Power 854.4 kW
Head 55.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

20/24 CME2

64.0
Overall Score
Efficiency 84.2%
Power 854.4 kW
Head 55.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

20/24 DV MEDI

63.4
Overall Score
Efficiency 94.2%
Power 941.6 kW
Head 68.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection