Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
4510.0 m³/hr Required
70.2 m Head Required
Application Requirements
Flow Rate: 4510.0 m³/hr
Head: 70.2 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
20/24 DV MEDI
700-600-710 6P
20 WLN 28C
20 D.S
20/24 CME
20 WLN 28B 6P
20 WLN 26A
16 WLN 35 C
24 WLN 46A
18/20 DME
Add to Shortlist
Overall Score 84.2/100 79.7/100 78.1/100 71.3/100 71.2/100 65.9/100 65.8/100 58.7/100 49.8/100 47.7/100
Pump Type
Efficiency (%) 96.1% 60.0% 87.1% 82.2% 86.0% 87.0% 88.5% 86.6% 87.1% 86.0%
Power Consumption (kW) 906.3 1437.9 1056.8 1049.6 1002.6 991.7 974.8 1541.8 1835.5 1003.2
Head Accuracy 70.9m 70.2m 74.9m 70.2m 70.2m 70.2m 70.2m 108.6m 130.1m 70.2m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 96.1%, Head error: 0.0% Efficiency: 60.0%, Head error: 0.0% Efficiency: 87.1%, Head error: 0.0% Efficiency: 82.2%, Head error: 0.0% Efficiency: 86.0%, Head error: 0.0% Efficiency: 87.0%, Head error: 0.0% Efficiency: 88.5%, Head error: 0.0% Efficiency: 86.6%, Head error: 0.0% Efficiency: 87.1%, Head error: 0.0% Efficiency: 86.0%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
20/24 DV MEDI
R19,847,860/year
906.3 kW × 8760h × R2.49/kWh
700-600-710 6P
R31,490,032/year
1437.9 kW × 8760h × R2.49/kWh
20 WLN 28C
R23,143,723/year
1056.8 kW × 8760h × R2.49/kWh
20 D.S
R22,985,430/year
1049.6 kW × 8760h × R2.49/kWh
20/24 CME
R21,957,028/year
1002.6 kW × 8760h × R2.49/kWh
20 WLN 28B 6P
R21,717,266/year
991.7 kW × 8760h × R2.49/kWh
20 WLN 26A
R21,349,171/year
974.8 kW × 8760h × R2.49/kWh
16 WLN 35 C
R33,764,610/year
1541.8 kW × 8760h × R2.49/kWh
24 WLN 46A
R40,198,501/year
1835.5 kW × 8760h × R2.49/kWh
18/20 DME
R21,969,795/year
1003.2 kW × 8760h × R2.49/kWh
10-Year Total Cost
20/24 DV MEDI
R248,479
Initial + 10-year energy cost
700-600-710 6P
R364,900
Initial + 10-year energy cost
20 WLN 28C
R281,437
Initial + 10-year energy cost
20 D.S
R279,854
Initial + 10-year energy cost
20/24 CME
R269,570
Initial + 10-year energy cost
20 WLN 28B 6P
R267,173
Initial + 10-year energy cost
20 WLN 26A
R263,492
Initial + 10-year energy cost
16 WLN 35 C
R387,646
Initial + 10-year energy cost
24 WLN 46A
R451,985
Initial + 10-year energy cost
18/20 DME
R269,698
Initial + 10-year energy cost
Annual Cost Comparison
20/24 DV MEDI
Baseline
Reference point
700-600-710 6P
-R11,642,171/year
Additional cost vs baseline
20 WLN 28C
-R3,295,862/year
Additional cost vs baseline
20 D.S
-R3,137,569/year
Additional cost vs baseline
20/24 CME
-R2,109,167/year
Additional cost vs baseline
20 WLN 28B 6P
-R1,869,406/year
Additional cost vs baseline
20 WLN 26A
-R1,501,311/year
Additional cost vs baseline
16 WLN 35 C
-R13,916,749/year
Additional cost vs baseline
24 WLN 46A
-R20,350,641/year
Additional cost vs baseline
18/20 DME
-R2,121,935/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 20/24 DV MEDI (96.1% efficiency)
Lowest Operating Cost: 20/24 DV MEDI (R19,847,860/year)
Annual Cost Range: R20,350,641 difference between highest and lowest
10-Year Impact: R203,506,407 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

20/24 DV MEDI

84.2
Overall Score
Efficiency 96.1%
Power 906.3 kW
Head 70.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

700-600-710 6P

79.7
Overall Score
Efficiency 60.0%
Power 1437.9 kW
Head 70.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

20 WLN 28C

78.1
Overall Score
Efficiency 87.1%
Power 1056.8 kW
Head 74.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

20 D.S

71.3
Overall Score
Efficiency 82.2%
Power 1049.6 kW
Head 70.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

20/24 CME

71.2
Overall Score
Efficiency 86.0%
Power 1002.6 kW
Head 70.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20 WLN 28B 6P

65.9
Overall Score
Efficiency 87.0%
Power 991.7 kW
Head 70.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

20 WLN 26A

65.8
Overall Score
Efficiency 88.5%
Power 974.8 kW
Head 70.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

16 WLN 35 C

58.7
Overall Score
Efficiency 86.6%
Power 1541.8 kW
Head 108.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

24 WLN 46A

49.8
Overall Score
Efficiency 87.1%
Power 1835.5 kW
Head 130.1 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

18/20 DME

47.7
Overall Score
Efficiency 86.0%
Power 1003.2 kW
Head 70.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection