Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
3936.0 m³/hr Required
8.4 m Head Required
Application Requirements
Flow Rate: 3936.0 m³/hr
Head: 8.4 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
8312-30 A331T
8312-24 361T
20 WLN 22A
8312-30 A332T
8312-24 360F
8312-24 362T
11 MQ H 1100VLT
8312-30 A330F
30 WLN 30C
24 WLN 26A
Add to Shortlist
Overall Score 79.1/100 78.9/100 74.0/100 70.7/100 70.4/100 63.8/100 63.7/100 59.2/100 56.0/100 55.9/100
Pump Type
Efficiency (%) 85.3% 85.0% 84.0% 87.5% 81.2% 85.5% 81.2% 83.5% 78.8% 85.4%
Power Consumption (kW) 110.9 106.0 107.3 103.0 134.4 105.4 198.0 107.9 172.8 335.6
Head Accuracy 8.8m 8.4m 8.4m 8.4m 10.2m 8.4m 15.0m 8.4m 12.7m 26.7m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 85.3%, Head error: 0.0% Efficiency: 85.0%, Head error: 0.0% Efficiency: 84.0%, Head error: 0.0% Efficiency: 87.5%, Head error: 0.0% Efficiency: 81.2%, Head error: 0.0% Efficiency: 85.5%, Head error: 0.0% Efficiency: 81.2%, Head error: 0.0% Efficiency: 83.5%, Head error: 0.0% Efficiency: 78.8%, Head error: 0.0% Efficiency: 85.4%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
8312-30 A331T
R2,429,542/year
110.9 kW × 8760h × R2.49/kWh
8312-24 361T
R2,321,269/year
106.0 kW × 8760h × R2.49/kWh
20 WLN 22A
R2,348,906/year
107.3 kW × 8760h × R2.49/kWh
8312-30 A332T
R2,254,955/year
103.0 kW × 8760h × R2.49/kWh
8312-24 360F
R2,942,900/year
134.4 kW × 8760h × R2.49/kWh
8312-24 362T
R2,307,691/year
105.4 kW × 8760h × R2.49/kWh
11 MQ H 1100VLT
R4,337,251/year
198.0 kW × 8760h × R2.49/kWh
8312-30 A330F
R2,362,966/year
107.9 kW × 8760h × R2.49/kWh
30 WLN 30C
R3,783,948/year
172.8 kW × 8760h × R2.49/kWh
24 WLN 26A
R7,350,669/year
335.6 kW × 8760h × R2.49/kWh
10-Year Total Cost
8312-30 A331T
R74,295
Initial + 10-year energy cost
8312-24 361T
R73,213
Initial + 10-year energy cost
20 WLN 22A
R73,489
Initial + 10-year energy cost
8312-30 A332T
R72,550
Initial + 10-year energy cost
8312-24 360F
R79,429
Initial + 10-year energy cost
8312-24 362T
R73,077
Initial + 10-year energy cost
11 MQ H 1100VLT
R93,373
Initial + 10-year energy cost
8312-30 A330F
R73,630
Initial + 10-year energy cost
30 WLN 30C
R87,839
Initial + 10-year energy cost
24 WLN 26A
R123,507
Initial + 10-year energy cost
Annual Cost Comparison
8312-30 A331T
Baseline
Reference point
8312-24 361T
+R108,274/year
Cost savings vs baseline
20 WLN 22A
+R80,636/year
Cost savings vs baseline
8312-30 A332T
+R174,587/year
Cost savings vs baseline
8312-24 360F
-R513,358/year
Additional cost vs baseline
8312-24 362T
+R121,852/year
Cost savings vs baseline
11 MQ H 1100VLT
-R1,907,709/year
Additional cost vs baseline
8312-30 A330F
+R66,576/year
Cost savings vs baseline
30 WLN 30C
-R1,354,405/year
Additional cost vs baseline
24 WLN 26A
-R4,921,127/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 8312-30 A332T (87.5% efficiency)
Lowest Operating Cost: 8312-30 A332T (R2,254,955/year)
Annual Cost Range: R5,095,714 difference between highest and lowest
10-Year Impact: R50,957,139 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

8312-30 A331T

79.1
Overall Score
Efficiency 85.3%
Power 110.9 kW
Head 8.8 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

8312-24 361T

78.9
Overall Score
Efficiency 85.0%
Power 106.0 kW
Head 8.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

20 WLN 22A

74.0
Overall Score
Efficiency 84.0%
Power 107.3 kW
Head 8.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

8312-30 A332T

70.7
Overall Score
Efficiency 87.5%
Power 103.0 kW
Head 8.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

8312-24 360F

70.4
Overall Score
Efficiency 81.2%
Power 134.4 kW
Head 10.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

8312-24 362T

63.8
Overall Score
Efficiency 85.5%
Power 105.4 kW
Head 8.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

11 MQ H 1100VLT

63.7
Overall Score
Efficiency 81.2%
Power 198.0 kW
Head 15.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

8312-30 A330F

59.2
Overall Score
Efficiency 83.5%
Power 107.9 kW
Head 8.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

30 WLN 30C

56.0
Overall Score
Efficiency 78.8%
Power 172.8 kW
Head 12.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

24 WLN 26A

55.9
Overall Score
Efficiency 85.4%
Power 335.6 kW
Head 26.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection