Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
3905.0 m³/hr Required
60.4 m Head Required
Application Requirements
Flow Rate: 3905.0 m³/hr
Head: 60.4 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
700-600-710 6P
20 WLN 26B
20/24 CME
20/24 CME2
20/24 DV MEDI
20 D.S
20 WLN 28B 6P
16 WLN 35 C
20 WLN 26A
20 WLN 28C
Add to Shortlist
Overall Score 83.4/100 82.4/100 80.5/100 80.5/100 80.4/100 76.0/100 73.0/100 67.2/100 65.6/100 61.9/100
Pump Type
Efficiency (%) 87.2% 73.0% 85.8% 85.8% 99.2% 82.0% 86.5% 88.1% 85.3% 85.2%
Power Consumption (kW) 777.8 880.4 802.3 802.3 823.6 874.9 831.6 1402.1 753.5 984.7
Head Accuracy 63.8m 60.4m 64.7m 64.7m 76.8m 67.5m 67.6m 116.0m 60.4m 78.9m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 87.2%, Head error: 0.0% Efficiency: 73.0%, Head error: 0.0% Efficiency: 85.8%, Head error: 0.0% Efficiency: 85.8%, Head error: 0.0% Efficiency: 99.2%, Head error: 0.0% Efficiency: 82.0%, Head error: 0.0% Efficiency: 86.5%, Head error: 0.0% Efficiency: 88.1%, Head error: 0.0% Efficiency: 85.3%, Head error: 0.0% Efficiency: 85.2%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
700-600-710 6P
R17,033,404/year
777.8 kW × 8760h × R2.49/kWh
20 WLN 26B
R19,281,724/year
880.4 kW × 8760h × R2.49/kWh
20/24 CME
R17,570,698/year
802.3 kW × 8760h × R2.49/kWh
20/24 CME2
R17,570,698/year
802.3 kW × 8760h × R2.49/kWh
20/24 DV MEDI
R18,035,767/year
823.6 kW × 8760h × R2.49/kWh
20 D.S
R19,161,252/year
874.9 kW × 8760h × R2.49/kWh
20 WLN 28B 6P
R18,211,274/year
831.6 kW × 8760h × R2.49/kWh
16 WLN 35 C
R30,705,618/year
1402.1 kW × 8760h × R2.49/kWh
20 WLN 26A
R16,501,343/year
753.5 kW × 8760h × R2.49/kWh
20 WLN 28C
R21,564,382/year
984.7 kW × 8760h × R2.49/kWh
10-Year Total Cost
700-600-710 6P
R220,334
Initial + 10-year energy cost
20 WLN 26B
R242,817
Initial + 10-year energy cost
20/24 CME
R225,707
Initial + 10-year energy cost
20/24 CME2
R225,707
Initial + 10-year energy cost
20/24 DV MEDI
R230,358
Initial + 10-year energy cost
20 D.S
R241,613
Initial + 10-year energy cost
20 WLN 28B 6P
R232,113
Initial + 10-year energy cost
16 WLN 35 C
R357,056
Initial + 10-year energy cost
20 WLN 26A
R215,013
Initial + 10-year energy cost
20 WLN 28C
R265,644
Initial + 10-year energy cost
Annual Cost Comparison
700-600-710 6P
Baseline
Reference point
20 WLN 26B
-R2,248,320/year
Additional cost vs baseline
20/24 CME
-R537,295/year
Additional cost vs baseline
20/24 CME2
-R537,295/year
Additional cost vs baseline
20/24 DV MEDI
-R1,002,363/year
Additional cost vs baseline
20 D.S
-R2,127,848/year
Additional cost vs baseline
20 WLN 28B 6P
-R1,177,870/year
Additional cost vs baseline
16 WLN 35 C
-R13,672,214/year
Additional cost vs baseline
20 WLN 26A
+R532,060/year
Cost savings vs baseline
20 WLN 28C
-R4,530,979/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 20/24 DV MEDI (99.2% efficiency)
Lowest Operating Cost: 20 WLN 26A (R16,501,343/year)
Annual Cost Range: R14,204,274 difference between highest and lowest
10-Year Impact: R142,042,743 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

700-600-710 6P

83.4
Overall Score
Efficiency 87.2%
Power 777.8 kW
Head 63.8 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

20 WLN 26B

82.4
Overall Score
Efficiency 73.0%
Power 880.4 kW
Head 60.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

20/24 CME

80.5
Overall Score
Efficiency 85.8%
Power 802.3 kW
Head 64.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

20/24 CME2

80.5
Overall Score
Efficiency 85.8%
Power 802.3 kW
Head 64.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

20/24 DV MEDI

80.4
Overall Score
Efficiency 99.2%
Power 823.6 kW
Head 76.8 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20 D.S

76.0
Overall Score
Efficiency 82.0%
Power 874.9 kW
Head 67.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

20 WLN 28B 6P

73.0
Overall Score
Efficiency 86.5%
Power 831.6 kW
Head 67.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

16 WLN 35 C

67.2
Overall Score
Efficiency 88.1%
Power 1402.1 kW
Head 116.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

20 WLN 26A

65.6
Overall Score
Efficiency 85.3%
Power 753.5 kW
Head 60.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

20 WLN 28C

61.9
Overall Score
Efficiency 85.2%
Power 984.7 kW
Head 78.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection