Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
387.7 m³/hr Required
102.7 m Head Required
Application Requirements
Flow Rate: 387.7 m³/hr
Head: 102.7 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
6/8 DME
6/8 DMP
SCP 150/580HA-132/4
VBK 35-22.5 3 STAGE
6 WLN 21A
VBK 35-22 3 Stage
150-125-315
9-11 2 STAGE MEDIVANE
PJ 200 AS
200-200-540 4P
Add to Shortlist
Overall Score 85.3/100 85.3/100 85.2/100 82.0/100 80.4/100 78.2/100 71.1/100 70.3/100 70.3/100 69.3/100
Pump Type
Efficiency (%) 82.0% 82.0% 78.4% 74.3% 76.0% 63.5% 77.7% 57.7% 71.0% 75.0%
Power Consumption (kW) 132.3 132.3 147.2 146.1 142.8 170.9 166.7 204.3 152.8 144.7
Head Accuracy 102.7m 102.7m 109.2m 102.7m 102.7m 102.7m 122.6m 111.6m 102.7m 102.7m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 82.0%, Head error: 0.0% Efficiency: 82.0%, Head error: 0.0% Efficiency: 78.4%, Head error: 0.0% Efficiency: 74.3%, Head error: 0.0% Efficiency: 76.0%, Head error: 0.0% Efficiency: 63.5%, Head error: 0.0% Efficiency: 77.7%, Head error: 0.0% Efficiency: 57.7%, Head error: 0.0% Efficiency: 71.0%, Head error: 0.0% Efficiency: 75.0%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
6/8 DME
R2,897,764/year
132.3 kW × 8760h × R2.49/kWh
6/8 DMP
R2,897,764/year
132.3 kW × 8760h × R2.49/kWh
SCP 150/580HA-132/4
R3,223,132/year
147.2 kW × 8760h × R2.49/kWh
VBK 35-22.5 3 STAGE
R3,199,371/year
146.1 kW × 8760h × R2.49/kWh
6 WLN 21A
R3,126,532/year
142.8 kW × 8760h × R2.49/kWh
VBK 35-22 3 Stage
R3,741,987/year
170.9 kW × 8760h × R2.49/kWh
150-125-315
R3,651,453/year
166.7 kW × 8760h × R2.49/kWh
9-11 2 STAGE MEDIVANE
R4,474,674/year
204.3 kW × 8760h × R2.49/kWh
PJ 200 AS
R3,346,714/year
152.8 kW × 8760h × R2.49/kWh
200-200-540 4P
R3,168,229/year
144.7 kW × 8760h × R2.49/kWh
10-Year Total Cost
6/8 DME
R78,978
Initial + 10-year energy cost
6/8 DMP
R78,978
Initial + 10-year energy cost
SCP 150/580HA-132/4
R82,231
Initial + 10-year energy cost
VBK 35-22.5 3 STAGE
R81,994
Initial + 10-year energy cost
6 WLN 21A
R81,265
Initial + 10-year energy cost
VBK 35-22 3 Stage
R87,420
Initial + 10-year energy cost
150-125-315
R86,515
Initial + 10-year energy cost
9-11 2 STAGE MEDIVANE
R94,747
Initial + 10-year energy cost
PJ 200 AS
R83,467
Initial + 10-year energy cost
200-200-540 4P
R81,682
Initial + 10-year energy cost
Annual Cost Comparison
6/8 DME
Baseline
Reference point
6/8 DMP
-R-0/year
Additional cost vs baseline
SCP 150/580HA-132/4
-R325,368/year
Additional cost vs baseline
VBK 35-22.5 3 STAGE
-R301,607/year
Additional cost vs baseline
6 WLN 21A
-R228,767/year
Additional cost vs baseline
VBK 35-22 3 Stage
-R844,223/year
Additional cost vs baseline
150-125-315
-R753,688/year
Additional cost vs baseline
9-11 2 STAGE MEDIVANE
-R1,576,910/year
Additional cost vs baseline
PJ 200 AS
-R448,950/year
Additional cost vs baseline
200-200-540 4P
-R270,465/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 6/8 DME (82.0% efficiency)
Lowest Operating Cost: 6/8 DME (R2,897,764/year)
Annual Cost Range: R1,576,910 difference between highest and lowest
10-Year Impact: R15,769,095 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

6/8 DME

85.3
Overall Score
Efficiency 82.0%
Power 132.3 kW
Head 102.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

6/8 DMP

85.3
Overall Score
Efficiency 82.0%
Power 132.3 kW
Head 102.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

SCP 150/580HA-132/4

85.2
Overall Score
Efficiency 78.4%
Power 147.2 kW
Head 109.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

VBK 35-22.5 3 STAGE

82.0
Overall Score
Efficiency 74.3%
Power 146.1 kW
Head 102.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

6 WLN 21A

80.4
Overall Score
Efficiency 76.0%
Power 142.8 kW
Head 102.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

VBK 35-22 3 Stage

78.2
Overall Score
Efficiency 63.5%
Power 170.9 kW
Head 102.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

150-125-315

71.1
Overall Score
Efficiency 77.7%
Power 166.7 kW
Head 122.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

9-11 2 STAGE MEDIVANE

70.3
Overall Score
Efficiency 57.7%
Power 204.3 kW
Head 111.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

PJ 200 AS

70.3
Overall Score
Efficiency 71.0%
Power 152.8 kW
Head 102.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

200-200-540 4P

69.3
Overall Score
Efficiency 75.0%
Power 144.7 kW
Head 102.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection