Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
3073.0 m³/hr Required
38.6 m Head Required
Application Requirements
Flow Rate: 3073.0 m³/hr
Head: 38.6 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
36 HC 6P
16 WLN 23C
20/24 DV CME
20 WLN 28B 8P
18/20 DME
20 WLN 26A
700-600-710 8P
20 WLN 26B
16 WLN 28C
20/24 DV MEDI
Add to Shortlist
Overall Score 79.5/100 78.3/100 76.5/100 74.4/100 72.9/100 65.8/100 64.0/100 60.5/100 59.7/100 58.9/100
Pump Type
Efficiency (%) 85.9% 89.6% 87.8% 81.4% 87.1% 83.6% 85.0% 83.3% 86.0% 89.4%
Power Consumption (kW) 403.4 411.3 464.0 433.4 531.6 461.5 380.3 440.4 593.0 781.4
Head Accuracy 41.4m 44.0m 48.6m 42.1m 55.3m 46.1m 38.6m 43.8m 60.9m 83.4m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 85.9%, Head error: 0.0% Efficiency: 89.6%, Head error: 0.0% Efficiency: 87.8%, Head error: 0.0% Efficiency: 81.4%, Head error: 0.0% Efficiency: 87.1%, Head error: 0.0% Efficiency: 83.6%, Head error: 0.0% Efficiency: 85.0%, Head error: 0.0% Efficiency: 83.3%, Head error: 0.0% Efficiency: 86.0%, Head error: 0.0% Efficiency: 89.4%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
36 HC 6P
R8,834,920/year
403.4 kW × 8760h × R2.49/kWh
16 WLN 23C
R9,008,477/year
411.3 kW × 8760h × R2.49/kWh
20/24 DV CME
R10,160,899/year
464.0 kW × 8760h × R2.49/kWh
20 WLN 28B 8P
R9,491,920/year
433.4 kW × 8760h × R2.49/kWh
18/20 DME
R11,643,135/year
531.6 kW × 8760h × R2.49/kWh
20 WLN 26A
R10,107,660/year
461.5 kW × 8760h × R2.49/kWh
700-600-710 8P
R8,328,022/year
380.3 kW × 8760h × R2.49/kWh
20 WLN 26B
R9,643,928/year
440.4 kW × 8760h × R2.49/kWh
16 WLN 28C
R12,986,174/year
593.0 kW × 8760h × R2.49/kWh
20/24 DV MEDI
R17,113,448/year
781.4 kW × 8760h × R2.49/kWh
10-Year Total Cost
36 HC 6P
R138,349
Initial + 10-year energy cost
16 WLN 23C
R140,085
Initial + 10-year energy cost
20/24 DV CME
R151,609
Initial + 10-year energy cost
20 WLN 28B 8P
R144,919
Initial + 10-year energy cost
18/20 DME
R166,431
Initial + 10-year energy cost
20 WLN 26A
R151,077
Initial + 10-year energy cost
700-600-710 8P
R133,280
Initial + 10-year energy cost
20 WLN 26B
R146,439
Initial + 10-year energy cost
16 WLN 28C
R179,862
Initial + 10-year energy cost
20/24 DV MEDI
R221,134
Initial + 10-year energy cost
Annual Cost Comparison
36 HC 6P
Baseline
Reference point
16 WLN 23C
-R173,558/year
Additional cost vs baseline
20/24 DV CME
-R1,325,979/year
Additional cost vs baseline
20 WLN 28B 8P
-R657,000/year
Additional cost vs baseline
18/20 DME
-R2,808,215/year
Additional cost vs baseline
20 WLN 26A
-R1,272,740/year
Additional cost vs baseline
700-600-710 8P
+R506,897/year
Cost savings vs baseline
20 WLN 26B
-R809,008/year
Additional cost vs baseline
16 WLN 28C
-R4,151,254/year
Additional cost vs baseline
20/24 DV MEDI
-R8,278,529/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 16 WLN 23C (89.6% efficiency)
Lowest Operating Cost: 700-600-710 8P (R8,328,022/year)
Annual Cost Range: R8,785,426 difference between highest and lowest
10-Year Impact: R87,854,259 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

36 HC 6P

79.5
Overall Score
Efficiency 85.9%
Power 403.4 kW
Head 41.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

16 WLN 23C

78.3
Overall Score
Efficiency 89.6%
Power 411.3 kW
Head 44.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

20/24 DV CME

76.5
Overall Score
Efficiency 87.8%
Power 464.0 kW
Head 48.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

20 WLN 28B 8P

74.4
Overall Score
Efficiency 81.4%
Power 433.4 kW
Head 42.1 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

18/20 DME

72.9
Overall Score
Efficiency 87.1%
Power 531.6 kW
Head 55.3 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20 WLN 26A

65.8
Overall Score
Efficiency 83.6%
Power 461.5 kW
Head 46.1 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

700-600-710 8P

64.0
Overall Score
Efficiency 85.0%
Power 380.3 kW
Head 38.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

20 WLN 26B

60.5
Overall Score
Efficiency 83.3%
Power 440.4 kW
Head 43.8 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

16 WLN 28C

59.7
Overall Score
Efficiency 86.0%
Power 593.0 kW
Head 60.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

20/24 DV MEDI

58.9
Overall Score
Efficiency 89.4%
Power 781.4 kW
Head 83.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection