Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
2868.0 m³/hr Required
54.2 m Head Required
Application Requirements
Flow Rate: 2868.0 m³/hr
Head: 54.2 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
18/20 DME
20 WLN 26A
16 WLN 28C
36 HC 6P
20 WLN 26B
20/24 CME
20/24 CME2
12 LNH 21A
20/24 DV MEDI
Morgenstond 1
Add to Shortlist
Overall Score 83.2/100 75.7/100 72.4/100 67.9/100 62.8/100 60.7/100 60.7/100 60.4/100 60.2/100 56.0/100
Pump Type
Efficiency (%) 87.1% 80.0% 88.2% 85.0% 75.6% 79.5% 79.5% 84.6% 86.1% 80.3%
Power Consumption (kW) 523.6 586.0 582.0 498.3 620.5 697.1 697.1 636.3 769.8 1203.5
Head Accuracy 58.3m 60.0m 65.6m 54.2m 60.1m 71.0m 71.0m 68.9m 84.8m 123.7m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 87.1%, Head error: 0.0% Efficiency: 80.0%, Head error: 0.0% Efficiency: 88.2%, Head error: 0.0% Efficiency: 85.0%, Head error: 0.0% Efficiency: 75.6%, Head error: 0.0% Efficiency: 79.5%, Head error: 0.0% Efficiency: 79.5%, Head error: 0.0% Efficiency: 84.6%, Head error: 0.0% Efficiency: 86.1%, Head error: 0.0% Efficiency: 80.3%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
18/20 DME
R11,466,512/year
523.6 kW × 8760h × R2.49/kWh
20 WLN 26A
R12,833,269/year
586.0 kW × 8760h × R2.49/kWh
16 WLN 28C
R12,745,296/year
582.0 kW × 8760h × R2.49/kWh
36 HC 6P
R10,913,646/year
498.3 kW × 8760h × R2.49/kWh
20 WLN 26B
R13,588,643/year
620.5 kW × 8760h × R2.49/kWh
20/24 CME
R15,266,008/year
697.1 kW × 8760h × R2.49/kWh
20/24 CME2
R15,266,008/year
697.1 kW × 8760h × R2.49/kWh
12 LNH 21A
R13,935,452/year
636.3 kW × 8760h × R2.49/kWh
20/24 DV MEDI
R16,858,357/year
769.8 kW × 8760h × R2.49/kWh
Morgenstond 1
R26,355,883/year
1203.5 kW × 8760h × R2.49/kWh
10-Year Total Cost
18/20 DME
R164,665
Initial + 10-year energy cost
20 WLN 26A
R178,333
Initial + 10-year energy cost
16 WLN 28C
R177,453
Initial + 10-year energy cost
36 HC 6P
R159,136
Initial + 10-year energy cost
20 WLN 26B
R185,886
Initial + 10-year energy cost
20/24 CME
R202,660
Initial + 10-year energy cost
20/24 CME2
R202,660
Initial + 10-year energy cost
12 LNH 21A
R189,355
Initial + 10-year energy cost
20/24 DV MEDI
R218,584
Initial + 10-year energy cost
Morgenstond 1
R313,559
Initial + 10-year energy cost
Annual Cost Comparison
18/20 DME
Baseline
Reference point
20 WLN 26A
-R1,366,757/year
Additional cost vs baseline
16 WLN 28C
-R1,278,785/year
Additional cost vs baseline
36 HC 6P
+R552,866/year
Cost savings vs baseline
20 WLN 26B
-R2,122,132/year
Additional cost vs baseline
20/24 CME
-R3,799,497/year
Additional cost vs baseline
20/24 CME2
-R3,799,497/year
Additional cost vs baseline
12 LNH 21A
-R2,468,940/year
Additional cost vs baseline
20/24 DV MEDI
-R5,391,846/year
Additional cost vs baseline
Morgenstond 1
-R14,889,372/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 16 WLN 28C (88.2% efficiency)
Lowest Operating Cost: 36 HC 6P (R10,913,646/year)
Annual Cost Range: R15,442,237 difference between highest and lowest
10-Year Impact: R154,422,375 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

18/20 DME

83.2
Overall Score
Efficiency 87.1%
Power 523.6 kW
Head 58.3 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

20 WLN 26A

75.7
Overall Score
Efficiency 80.0%
Power 586.0 kW
Head 60.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

16 WLN 28C

72.4
Overall Score
Efficiency 88.2%
Power 582.0 kW
Head 65.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

36 HC 6P

67.9
Overall Score
Efficiency 85.0%
Power 498.3 kW
Head 54.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

20 WLN 26B

62.8
Overall Score
Efficiency 75.6%
Power 620.5 kW
Head 60.1 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20/24 CME

60.7
Overall Score
Efficiency 79.5%
Power 697.1 kW
Head 71.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

20/24 CME2

60.7
Overall Score
Efficiency 79.5%
Power 697.1 kW
Head 71.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

12 LNH 21A

60.4
Overall Score
Efficiency 84.6%
Power 636.3 kW
Head 68.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

20/24 DV MEDI

60.2
Overall Score
Efficiency 86.1%
Power 769.8 kW
Head 84.8 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

Morgenstond 1

56.0
Overall Score
Efficiency 80.3%
Power 1203.5 kW
Head 123.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection