Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
2450.0 m³/hr Required
53.9 m Head Required
Application Requirements
Flow Rate: 2450.0 m³/hr
Head: 53.9 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
16 WLN 28C
18/20 DME
12 LNH 21A
12 WLN 17A
36 HC 6P
20 WLN 26A
12 LNH 21B
8/10 DESC
Morgenstond 1
20/24 CME
Add to Shortlist
Overall Score 75.4/100 70.2/100 65.9/100 65.1/100 63.5/100 60.4/100 56.4/100 55.2/100 48.8/100 48.2/100
Pump Type
Efficiency (%) 88.6% 84.9% 87.8% 70.0% 85.0% 73.7% 84.2% 62.6% 78.7% 74.5%
Power Consumption (kW) 546.7 500.8 607.5 514.1 423.4 570.2 586.4 681.5 1125.3 651.8
Head Accuracy 72.6m 63.7m 79.9m 53.9m 53.9m 63.0m 73.9m 63.9m 132.6m 72.8m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 88.6%, Head error: 0.0% Efficiency: 84.9%, Head error: 0.0% Efficiency: 87.8%, Head error: 0.0% Efficiency: 70.0%, Head error: 0.0% Efficiency: 85.0%, Head error: 0.0% Efficiency: 73.7%, Head error: 0.0% Efficiency: 84.2%, Head error: 0.0% Efficiency: 62.6%, Head error: 0.0% Efficiency: 78.7%, Head error: 0.0% Efficiency: 74.5%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
16 WLN 28C
R11,971,876/year
546.7 kW × 8760h × R2.49/kWh
18/20 DME
R10,966,885/year
500.8 kW × 8760h × R2.49/kWh
12 LNH 21A
R13,303,681/year
607.5 kW × 8760h × R2.49/kWh
12 WLN 17A
R11,258,155/year
514.1 kW × 8760h × R2.49/kWh
36 HC 6P
R9,271,431/year
423.4 kW × 8760h × R2.49/kWh
20 WLN 26A
R12,487,796/year
570.2 kW × 8760h × R2.49/kWh
12 LNH 21B
R12,842,642/year
586.4 kW × 8760h × R2.49/kWh
8/10 DESC
R14,923,799/year
681.5 kW × 8760h × R2.49/kWh
Morgenstond 1
R24,644,749/year
1125.3 kW × 8760h × R2.49/kWh
20/24 CME
R14,274,464/year
651.8 kW × 8760h × R2.49/kWh
10-Year Total Cost
16 WLN 28C
R169,719
Initial + 10-year energy cost
18/20 DME
R159,669
Initial + 10-year energy cost
12 LNH 21A
R183,037
Initial + 10-year energy cost
12 WLN 17A
R162,582
Initial + 10-year energy cost
36 HC 6P
R142,714
Initial + 10-year energy cost
20 WLN 26A
R174,878
Initial + 10-year energy cost
12 LNH 21B
R178,426
Initial + 10-year energy cost
8/10 DESC
R199,238
Initial + 10-year energy cost
Morgenstond 1
R296,447
Initial + 10-year energy cost
20/24 CME
R192,745
Initial + 10-year energy cost
Annual Cost Comparison
16 WLN 28C
Baseline
Reference point
18/20 DME
+R1,004,991/year
Cost savings vs baseline
12 LNH 21A
-R1,331,805/year
Additional cost vs baseline
12 WLN 17A
+R713,721/year
Cost savings vs baseline
36 HC 6P
+R2,700,445/year
Cost savings vs baseline
20 WLN 26A
-R515,920/year
Additional cost vs baseline
12 LNH 21B
-R870,766/year
Additional cost vs baseline
8/10 DESC
-R2,951,923/year
Additional cost vs baseline
Morgenstond 1
-R12,672,873/year
Additional cost vs baseline
20/24 CME
-R2,302,588/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 16 WLN 28C (88.6% efficiency)
Lowest Operating Cost: 36 HC 6P (R9,271,431/year)
Annual Cost Range: R15,373,318 difference between highest and lowest
10-Year Impact: R153,733,182 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

16 WLN 28C

75.4
Overall Score
Efficiency 88.6%
Power 546.7 kW
Head 72.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

18/20 DME

70.2
Overall Score
Efficiency 84.9%
Power 500.8 kW
Head 63.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

12 LNH 21A

65.9
Overall Score
Efficiency 87.8%
Power 607.5 kW
Head 79.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

12 WLN 17A

65.1
Overall Score
Efficiency 70.0%
Power 514.1 kW
Head 53.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

36 HC 6P

63.5
Overall Score
Efficiency 85.0%
Power 423.4 kW
Head 53.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

20 WLN 26A

60.4
Overall Score
Efficiency 73.7%
Power 570.2 kW
Head 63.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

12 LNH 21B

56.4
Overall Score
Efficiency 84.2%
Power 586.4 kW
Head 73.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

8/10 DESC

55.2
Overall Score
Efficiency 62.6%
Power 681.5 kW
Head 63.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

Morgenstond 1

48.8
Overall Score
Efficiency 78.7%
Power 1125.3 kW
Head 132.6 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

20/24 CME

48.2
Overall Score
Efficiency 74.5%
Power 651.8 kW
Head 72.8 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection