Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
2271.2 m³/hr Required
132.9 m Head Required
Application Requirements
Flow Rate: 2271.2 m³/hr
Head: 132.9 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
18/22 MEDIVANE
Morgenstond 1
VBK 620/022-4S
VBK 620/022-4S (Test Curve)
14/18 EME
12X16X23H DSJH
16 WLN 35 C
DVMS 4000-125
24 WLN 46A
8X10X13 3S
Add to Shortlist
Overall Score 76.1/100 68.9/100 68.6/100 68.6/100 66.3/100 47.1/100 38.6/100 33.5/100 32.9/100 -28.1/100
Pump Type
Efficiency (%) 87.0% 77.0% 82.3% 82.3% 78.0% 83.0% 71.6% 75.2% 75.0% 84.8%
Power Consumption (kW) 966.0 1092.2 1335.9 1335.9 1215.7 991.0 1148.8 2220.5 1096.7 9952.8
Head Accuracy 135.8m 135.9m 177.7m 177.7m 153.3m 132.9m 132.9m 269.7m 132.9m 1363.5m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 87.0%, Head error: 0.0% Efficiency: 77.0%, Head error: 0.0% Efficiency: 82.3%, Head error: 0.0% Efficiency: 82.3%, Head error: 0.0% Efficiency: 78.0%, Head error: 0.0% Efficiency: 83.0%, Head error: 0.0% Efficiency: 71.6%, Head error: 0.0% Efficiency: 75.2%, Head error: 0.0% Efficiency: 75.0%, Head error: 0.0% Efficiency: 84.8%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
18/22 MEDIVANE
R21,155,772/year
966.0 kW × 8760h × R2.49/kWh
Morgenstond 1
R23,919,815/year
1092.2 kW × 8760h × R2.49/kWh
VBK 620/022-4S
R29,257,108/year
1335.9 kW × 8760h × R2.49/kWh
VBK 620/022-4S (Test Curve)
R29,257,108/year
1335.9 kW × 8760h × R2.49/kWh
14/18 EME
R26,624,356/year
1215.7 kW × 8760h × R2.49/kWh
12X16X23H DSJH
R21,702,659/year
991.0 kW × 8760h × R2.49/kWh
16 WLN 35 C
R25,158,107/year
1148.8 kW × 8760h × R2.49/kWh
DVMS 4000-125
R48,628,600/year
2220.5 kW × 8760h × R2.49/kWh
24 WLN 46A
R24,017,599/year
1096.7 kW × 8760h × R2.49/kWh
8X10X13 3S
R217,965,422/year
9952.8 kW × 8760h × R2.49/kWh
10-Year Total Cost
18/22 MEDIVANE
R261,558
Initial + 10-year energy cost
Morgenstond 1
R289,198
Initial + 10-year energy cost
VBK 620/022-4S
R342,571
Initial + 10-year energy cost
VBK 620/022-4S (Test Curve)
R342,571
Initial + 10-year energy cost
14/18 EME
R316,244
Initial + 10-year energy cost
12X16X23H DSJH
R267,027
Initial + 10-year energy cost
16 WLN 35 C
R301,581
Initial + 10-year energy cost
DVMS 4000-125
R536,286
Initial + 10-year energy cost
24 WLN 46A
R290,176
Initial + 10-year energy cost
8X10X13 3S
R2,229,654
Initial + 10-year energy cost
Annual Cost Comparison
18/22 MEDIVANE
Baseline
Reference point
Morgenstond 1
-R2,764,043/year
Additional cost vs baseline
VBK 620/022-4S
-R8,101,336/year
Additional cost vs baseline
VBK 620/022-4S (Test Curve)
-R8,101,336/year
Additional cost vs baseline
14/18 EME
-R5,468,583/year
Additional cost vs baseline
12X16X23H DSJH
-R546,887/year
Additional cost vs baseline
16 WLN 35 C
-R4,002,334/year
Additional cost vs baseline
DVMS 4000-125
-R27,472,827/year
Additional cost vs baseline
24 WLN 46A
-R2,861,826/year
Additional cost vs baseline
8X10X13 3S
-R196,809,650/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 18/22 MEDIVANE (87.0% efficiency)
Lowest Operating Cost: 18/22 MEDIVANE (R21,155,772/year)
Annual Cost Range: R196,809,650 difference between highest and lowest
10-Year Impact: R1,968,096,498 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

18/22 MEDIVANE

76.1
Overall Score
Efficiency 87.0%
Power 966.0 kW
Head 135.8 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

Morgenstond 1

68.9
Overall Score
Efficiency 77.0%
Power 1092.2 kW
Head 135.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

VBK 620/022-4S

68.6
Overall Score
Efficiency 82.3%
Power 1335.9 kW
Head 177.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

VBK 620/022-4S (Test Curve)

68.6
Overall Score
Efficiency 82.3%
Power 1335.9 kW
Head 177.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

14/18 EME

66.3
Overall Score
Efficiency 78.0%
Power 1215.7 kW
Head 153.3 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

12X16X23H DSJH

47.1
Overall Score
Efficiency 83.0%
Power 991.0 kW
Head 132.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

16 WLN 35 C

38.6
Overall Score
Efficiency 71.6%
Power 1148.8 kW
Head 132.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

DVMS 4000-125

33.5
Overall Score
Efficiency 75.2%
Power 2220.5 kW
Head 269.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

24 WLN 46A

32.9
Overall Score
Efficiency 75.0%
Power 1096.7 kW
Head 132.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

8X10X13 3S

-28.1
Overall Score
Efficiency 84.8%
Power 9952.8 kW
Head 1363.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection