Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
1756.8 m³/hr Required
135.0 m Head Required
Application Requirements
Flow Rate: 1756.8 m³/hr
Head: 135.0 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
10 WLN 26A
400-600
14/18 EME
18/22 MEDIVANE
12X16X23H DSJH
VBK 620/022-4S
VBK 620/022-4S (Test Curve)
300-250-600
PJ 200
Morgenstond 1
Add to Shortlist
Overall Score 82.6/100 82.6/100 75.2/100 72.0/100 70.6/100 58.6/100 58.6/100 51.0/100 49.0/100 48.6/100
Pump Type
Efficiency (%) 82.5% 79.0% 79.9% 87.2% 84.5% 79.3% 79.3% 76.0% 73.7% 69.3%
Power Consumption (kW) 783.4 818.1 910.2 899.6 764.8 1184.7 1184.7 850.4 1841.8 980.7
Head Accuracy 135.0m 135.0m 152.0m 163.9m 135.0m 196.2m 196.2m 135.0m 283.5m 141.9m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 82.5%, Head error: 0.0% Efficiency: 79.0%, Head error: 0.0% Efficiency: 79.9%, Head error: 0.0% Efficiency: 87.2%, Head error: 0.0% Efficiency: 84.5%, Head error: 0.0% Efficiency: 79.3%, Head error: 0.0% Efficiency: 79.3%, Head error: 0.0% Efficiency: 76.0%, Head error: 0.0% Efficiency: 73.7%, Head error: 0.0% Efficiency: 69.3%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
10 WLN 26A
R17,155,869/year
783.4 kW × 8760h × R2.49/kWh
400-600
R17,915,930/year
818.1 kW × 8760h × R2.49/kWh
14/18 EME
R19,933,906/year
910.2 kW × 8760h × R2.49/kWh
18/22 MEDIVANE
R19,701,634/year
899.6 kW × 8760h × R2.49/kWh
12X16X23H DSJH
R16,749,821/year
764.8 kW × 8760h × R2.49/kWh
VBK 620/022-4S
R25,945,872/year
1184.7 kW × 8760h × R2.49/kWh
VBK 620/022-4S (Test Curve)
R25,945,872/year
1184.7 kW × 8760h × R2.49/kWh
300-250-600
R18,623,147/year
850.4 kW × 8760h × R2.49/kWh
PJ 200
R40,334,369/year
1841.8 kW × 8760h × R2.49/kWh
Morgenstond 1
R21,476,761/year
980.7 kW × 8760h × R2.49/kWh
10-Year Total Cost
10 WLN 26A
R221,559
Initial + 10-year energy cost
400-600
R229,159
Initial + 10-year energy cost
14/18 EME
R249,339
Initial + 10-year energy cost
18/22 MEDIVANE
R247,016
Initial + 10-year energy cost
12X16X23H DSJH
R217,498
Initial + 10-year energy cost
VBK 620/022-4S
R309,459
Initial + 10-year energy cost
VBK 620/022-4S (Test Curve)
R309,459
Initial + 10-year energy cost
300-250-600
R236,231
Initial + 10-year energy cost
PJ 200
R453,344
Initial + 10-year energy cost
Morgenstond 1
R264,768
Initial + 10-year energy cost
Annual Cost Comparison
10 WLN 26A
Baseline
Reference point
400-600
-R760,061/year
Additional cost vs baseline
14/18 EME
-R2,778,037/year
Additional cost vs baseline
18/22 MEDIVANE
-R2,545,766/year
Additional cost vs baseline
12X16X23H DSJH
+R406,048/year
Cost savings vs baseline
VBK 620/022-4S
-R8,790,003/year
Additional cost vs baseline
VBK 620/022-4S (Test Curve)
-R8,790,003/year
Additional cost vs baseline
300-250-600
-R1,467,278/year
Additional cost vs baseline
PJ 200
-R23,178,500/year
Additional cost vs baseline
Morgenstond 1
-R4,320,892/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 18/22 MEDIVANE (87.2% efficiency)
Lowest Operating Cost: 12X16X23H DSJH (R16,749,821/year)
Annual Cost Range: R23,584,548 difference between highest and lowest
10-Year Impact: R235,845,480 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

10 WLN 26A

82.6
Overall Score
Efficiency 82.5%
Power 783.4 kW
Head 135.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

400-600

82.6
Overall Score
Efficiency 79.0%
Power 818.1 kW
Head 135.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

14/18 EME

75.2
Overall Score
Efficiency 79.9%
Power 910.2 kW
Head 152.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

18/22 MEDIVANE

72.0
Overall Score
Efficiency 87.2%
Power 899.6 kW
Head 163.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

12X16X23H DSJH

70.6
Overall Score
Efficiency 84.5%
Power 764.8 kW
Head 135.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

VBK 620/022-4S

58.6
Overall Score
Efficiency 79.3%
Power 1184.7 kW
Head 196.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

VBK 620/022-4S (Test Curve)

58.6
Overall Score
Efficiency 79.3%
Power 1184.7 kW
Head 196.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

300-250-600

51.0
Overall Score
Efficiency 76.0%
Power 850.4 kW
Head 135.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

PJ 200

49.0
Overall Score
Efficiency 73.7%
Power 1841.8 kW
Head 283.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

Morgenstond 1

48.6
Overall Score
Efficiency 69.3%
Power 980.7 kW
Head 141.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection