Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
1587.0 m³/hr Required
23.0 m Head Required
Application Requirements
Flow Rate: 1587.0 m³/hr
Head: 23.0 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
14/16 BLE
28 HC 6P
32 HC 8P
12 WLN 14A
14 WLN 19A
12 WLN 14B
12/14 BLE
12/10 AH WARMAN SLURRY
12 WLN 21B
12 WLN 17B
Add to Shortlist
Overall Score 83.3/100 81.5/100 77.2/100 74.7/100 68.9/100 68.0/100 67.8/100 65.5/100 64.5/100 64.2/100
Pump Type
Efficiency (%) 80.1% 84.7% 80.0% 80.0% 79.7% 84.4% 83.7% 85.5% 85.9% 87.1%
Power Consumption (kW) 139.7 127.5 124.3 129.2 169.9 186.3 157.7 165.2 175.7 189.8
Head Accuracy 25.9m 25.0m 23.0m 23.9m 31.3m 36.4m 30.5m 32.7m 34.9m 38.2m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 80.1%, Head error: 0.0% Efficiency: 84.7%, Head error: 0.0% Efficiency: 80.0%, Head error: 0.0% Efficiency: 80.0%, Head error: 0.0% Efficiency: 79.7%, Head error: 0.0% Efficiency: 84.4%, Head error: 0.0% Efficiency: 83.7%, Head error: 0.0% Efficiency: 85.5%, Head error: 0.0% Efficiency: 85.9%, Head error: 0.0% Efficiency: 87.1%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
14/16 BLE
R3,059,561/year
139.7 kW × 8760h × R2.49/kWh
28 HC 6P
R2,792,841/year
127.5 kW × 8760h × R2.49/kWh
32 HC 8P
R2,722,871/year
124.3 kW × 8760h × R2.49/kWh
12 WLN 14A
R2,829,414/year
129.2 kW × 8760h × R2.49/kWh
14 WLN 19A
R3,721,533/year
169.9 kW × 8760h × R2.49/kWh
12 WLN 14B
R4,080,518/year
186.3 kW × 8760h × R2.49/kWh
12/14 BLE
R3,453,740/year
157.7 kW × 8760h × R2.49/kWh
12/10 AH WARMAN SLURRY
R3,618,296/year
165.2 kW × 8760h × R2.49/kWh
12 WLN 21B
R3,847,064/year
175.7 kW × 8760h × R2.49/kWh
12 WLN 17B
R4,156,554/year
189.8 kW × 8760h × R2.49/kWh
10-Year Total Cost
14/16 BLE
R80,596
Initial + 10-year energy cost
28 HC 6P
R77,928
Initial + 10-year energy cost
32 HC 8P
R77,229
Initial + 10-year energy cost
12 WLN 14A
R78,294
Initial + 10-year energy cost
14 WLN 19A
R87,215
Initial + 10-year energy cost
12 WLN 14B
R90,805
Initial + 10-year energy cost
12/14 BLE
R84,537
Initial + 10-year energy cost
12/10 AH WARMAN SLURRY
R86,183
Initial + 10-year energy cost
12 WLN 21B
R88,471
Initial + 10-year energy cost
12 WLN 17B
R91,566
Initial + 10-year energy cost
Annual Cost Comparison
14/16 BLE
Baseline
Reference point
28 HC 6P
+R266,720/year
Cost savings vs baseline
32 HC 8P
+R336,691/year
Cost savings vs baseline
12 WLN 14A
+R230,147/year
Cost savings vs baseline
14 WLN 19A
-R661,971/year
Additional cost vs baseline
12 WLN 14B
-R1,020,956/year
Additional cost vs baseline
12/14 BLE
-R394,178/year
Additional cost vs baseline
12/10 AH WARMAN SLURRY
-R558,735/year
Additional cost vs baseline
12 WLN 21B
-R787,502/year
Additional cost vs baseline
12 WLN 17B
-R1,096,993/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 12 WLN 17B (87.1% efficiency)
Lowest Operating Cost: 32 HC 8P (R2,722,871/year)
Annual Cost Range: R1,433,684 difference between highest and lowest
10-Year Impact: R14,336,835 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

14/16 BLE

83.3
Overall Score
Efficiency 80.1%
Power 139.7 kW
Head 25.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

28 HC 6P

81.5
Overall Score
Efficiency 84.7%
Power 127.5 kW
Head 25.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

32 HC 8P

77.2
Overall Score
Efficiency 80.0%
Power 124.3 kW
Head 23.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

12 WLN 14A

74.7
Overall Score
Efficiency 80.0%
Power 129.2 kW
Head 23.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

14 WLN 19A

68.9
Overall Score
Efficiency 79.7%
Power 169.9 kW
Head 31.3 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

12 WLN 14B

68.0
Overall Score
Efficiency 84.4%
Power 186.3 kW
Head 36.4 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

12/14 BLE

67.8
Overall Score
Efficiency 83.7%
Power 157.7 kW
Head 30.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

12/10 AH WARMAN SLURRY

65.5
Overall Score
Efficiency 85.5%
Power 165.2 kW
Head 32.7 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

12 WLN 21B

64.5
Overall Score
Efficiency 85.9%
Power 175.7 kW
Head 34.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

12 WLN 17B

64.2
Overall Score
Efficiency 87.1%
Power 189.8 kW
Head 38.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection