Pump Performance Comparison

Intelligent side-by-side analysis powered by APE engineering expertise

10 Pumps Analyzed
1000.0 m³/hr Required
56.5 m Head Required
Application Requirements
Flow Rate: 1000.0 m³/hr
Head: 56.5 m
Application: Water Supply
Liquid: Clean Water

📊 Detailed Performance Comparison

Compare key specifications and performance metrics across all pump options

sort Sort by:
Parameter
10 WLN 18A
8/10 CME - TA
12/14 BDY
14/12BDY
10 NHTB
10/12 BLE
300-250-600
PJ 250 BS
250-250-450 4P
12 WLN 17B
Add to Shortlist
Overall Score 80.6/100 75.4/100 74.2/100 74.2/100 72.6/100 67.8/100 67.5/100 65.3/100 64.4/100 64.4/100
Pump Type
Efficiency (%) 82.8% 84.5% 84.2% 84.2% 78.0% 82.4% 82.9% 80.4% 81.5% 72.0%
Power Consumption (kW) 200.5 190.2 245.8 245.8 200.1 186.9 411.7 243.3 188.9 222.9
Head Accuracy 60.9m 59.0m 76.0m 76.0m 57.3m 56.5m 125.2m 71.8m 56.5m 58.9m
Impeller Size (mm)
Operating Point Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range Within Range
Selection Reason Efficiency: 82.8%, Head error: 0.0% Efficiency: 84.5%, Head error: 0.0% Efficiency: 84.2%, Head error: 0.0% Efficiency: 84.2%, Head error: 0.0% Efficiency: 78.0%, Head error: 0.0% Efficiency: 82.4%, Head error: 0.0% Efficiency: 82.9%, Head error: 0.0% Efficiency: 80.4%, Head error: 0.0% Efficiency: 81.5%, Head error: 0.0% Efficiency: 72.0%, Head error: 0.0%
Actions

* Indicates extrapolated values beyond tested curve range

💰 Lifecycle Cost Analysis

Compare operating costs and long-term financial impact over 10-year lifespan

Annual Energy Cost
10 WLN 18A
R4,391,016/year
200.5 kW × 8760h × R2.49/kWh
8/10 CME - TA
R4,164,854/year
190.2 kW × 8760h × R2.49/kWh
12/14 BDY
R5,383,370/year
245.8 kW × 8760h × R2.49/kWh
14/12BDY
R5,383,370/year
245.8 kW × 8760h × R2.49/kWh
10 NHTB
R4,381,686/year
200.1 kW × 8760h × R2.49/kWh
10/12 BLE
R4,093,942/year
186.9 kW × 8760h × R2.49/kWh
300-250-600
R9,016,712/year
411.7 kW × 8760h × R2.49/kWh
PJ 250 BS
R5,328,095/year
243.3 kW × 8760h × R2.49/kWh
250-250-450 4P
R4,137,151/year
188.9 kW × 8760h × R2.49/kWh
12 WLN 17B
R4,882,233/year
222.9 kW × 8760h × R2.49/kWh
10-Year Total Cost
10 WLN 18A
R93,910
Initial + 10-year energy cost
8/10 CME - TA
R91,649
Initial + 10-year energy cost
12/14 BDY
R103,834
Initial + 10-year energy cost
14/12BDY
R103,834
Initial + 10-year energy cost
10 NHTB
R93,817
Initial + 10-year energy cost
10/12 BLE
R90,939
Initial + 10-year energy cost
300-250-600
R140,167
Initial + 10-year energy cost
PJ 250 BS
R103,281
Initial + 10-year energy cost
250-250-450 4P
R91,372
Initial + 10-year energy cost
12 WLN 17B
R98,822
Initial + 10-year energy cost
Annual Cost Comparison
10 WLN 18A
Baseline
Reference point
8/10 CME - TA
+R226,161/year
Cost savings vs baseline
12/14 BDY
-R992,355/year
Additional cost vs baseline
14/12BDY
-R992,355/year
Additional cost vs baseline
10 NHTB
+R9,329/year
Cost savings vs baseline
10/12 BLE
+R297,073/year
Cost savings vs baseline
300-250-600
-R4,625,696/year
Additional cost vs baseline
PJ 250 BS
-R937,079/year
Additional cost vs baseline
250-250-450 4P
+R253,865/year
Cost savings vs baseline
12 WLN 17B
-R491,217/year
Additional cost vs baseline
Cost Analysis Summary
Most Efficient: 8/10 CME - TA (84.5% efficiency)
Lowest Operating Cost: 10/12 BLE (R4,093,942/year)
Annual Cost Range: R4,922,770 difference between highest and lowest
10-Year Impact: R49,227,696 total savings potential

🔧 Individual Pump Overview

Detailed cards view with performance metrics and direct actions for each pump option

BEST MATCH

10 WLN 18A

80.6
Overall Score
Efficiency 82.8%
Power 200.5 kW
Head 60.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 2

8/10 CME - TA

75.4
Overall Score
Efficiency 84.5%
Power 190.2 kW
Head 59.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 3

12/14 BDY

74.2
Overall Score
Efficiency 84.2%
Power 245.8 kW
Head 76.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 4

14/12BDY

74.2
Overall Score
Efficiency 84.2%
Power 245.8 kW
Head 76.0 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 5

10 NHTB

72.6
Overall Score
Efficiency 78.0%
Power 200.1 kW
Head 57.3 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 6

10/12 BLE

67.8
Overall Score
Efficiency 82.4%
Power 186.9 kW
Head 56.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 7

300-250-600

67.5
Overall Score
Efficiency 82.9%
Power 411.7 kW
Head 125.2 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 8

PJ 250 BS

65.3
Overall Score
Efficiency 80.4%
Power 243.3 kW
Head 71.8 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 9

250-250-450 4P

64.4
Overall Score
Efficiency 81.5%
Power 188.9 kW
Head 56.5 m
Impeller mm
Manufacturer APE Pumps
description Full Report
RANK 10

12 WLN 17B

64.4
Overall Score
Efficiency 72.0%
Power 222.9 kW
Head 58.9 m
Impeller mm
Manufacturer APE Pumps
description Full Report
picture_as_pdfDownload Comparison Report arrow_backNew Selection