Compare key specifications and performance metrics across all pump options
| Parameter |
300-250-600
|
Umgeni Verulam July 2022
|
8 WLN 29B
|
10/12 GME
|
10 WLN 22A
|
18 HC 1214 4P 6ST SABS
|
10/12 DESC
|
PJ 250 AS
|
8/10 DME
|
PJ 258 H
|
|---|---|---|---|---|---|---|---|---|---|---|
| Add to Shortlist | ||||||||||
| Overall Score | 86.2/100 | 76.8/100 | 71.0/100 | 70.9/100 | 67.9/100 | 65.1/100 | 62.7/100 | 60.2/100 | 58.0/100 | 56.5/100 |
| Pump Type | ||||||||||
| Efficiency (%) | 82.9% | 79.2% | 74.4% | 85.3% | 78.0% | 75.2% | 75.0% | 81.5% | 87.0% | 80.0% |
| Power Consumption (kW) | 411.7 | 460.8 | 618.0 | 622.6 | 407.7 | 455.7 | 406.9 | 374.5 | 350.8 | 381.5 |
| Head Accuracy | 125.2m | 133.9m | 168.8m | 194.9m | 116.7m | 125.8m | 112.0m | 112.0m | 112.0m | 112.0m |
| Impeller Size (mm) | ||||||||||
| Operating Point | Within Range | Within Range | Within Range | Within Range | Within Range | Within Range | Within Range | Within Range | Within Range | Within Range |
| Selection Reason | Efficiency: 82.9%, Head error: 0.0% | Efficiency: 79.2%, Head error: 0.0% | Efficiency: 74.4%, Head error: 0.0% | Efficiency: 85.3%, Head error: 0.0% | Efficiency: 78.0%, Head error: 0.0% | Efficiency: 75.2%, Head error: 0.0% | Efficiency: 75.0%, Head error: 0.0% | Efficiency: 81.5%, Head error: 0.0% | Efficiency: 87.0%, Head error: 0.0% | Efficiency: 80.0%, Head error: 0.0% |
| Actions |
* Indicates extrapolated values beyond tested curve range
Compare operating costs and long-term financial impact over 10-year lifespan
Detailed cards view with performance metrics and direct actions for each pump option